Service and emergencies · calls accepted from 7 AM to 11 PM

R.B.Q. 5840-4443-01 · CMMTQ Member · 514 917-5525

Service · multi-unit, commercial, and light industrial

Boilers and Boiler Rooms

Boiler rooms for apartment buildings, domestic hot water for condo towers, unit heaters for garages and warehouses, corridor fresh air systems. Gas installations that cannot tolerate downtime and require a license to service.

License, Affiliations, and Suppliers
  • Régie du bâtiment du Québec
  • CMMTQ
  • AECQ
  • Quebec Construction Commission
  • APCHQ
  • Wolseley
  • Master
  • Federated Insurance
  • Régie du bâtiment du Québec
  • CMMTQ
  • AECQ
  • Quebec Construction Commission
  • APCHQ
  • Wolseley
  • Master
  • Federated Insurance
5840-4443-01

Our RBQ license number, verifiable in the public registry

January 1, 2027

Start of mandatory consumption reporting for buildings with 50 units or more

7 a.m. to 11 p.m.

Calls accepted seven days a week for a downed boiler room

What the Service Covers

Maintenance, repair, replacement, and commissioning of natural gas appliances in multi-unit buildings: heating boilers, centralized domestic hot water production, suspended unit heaters, make-up air units. This also includes connections, venting, and safety devices.

The owner personally executes all mandates, with twenty years of experience in building mechanics. R.B.Q. License 5840-4443-01, member of the CMMTQ.

The Boiler Room of an Apartment Building

A boiler room is not just a big furnace. It is a system where the boiler is only one part: circulation pumps, expansion tanks, safety valves, aquastats and controls, and the distribution network. A heating failure in a building is just as likely to come from circulation as from combustion, which is why a serious diagnosis is never limited to the appliance itself.

We handle both repairs and preventive maintenance. In a building where twenty households depend on a single appliance, annual maintenance is not a luxury expense: it is what prevents an emergency call on a Sunday in January and the collective complaint that follows.

Domestic Hot Water for a Condo Tower

Centralized hot water production poses a problem that single-family residential homes do not face: distance. Between the boiler room and the top floor, the water cools down, which requires a recirculation loop and a maintenance temperature. A poorly balanced network results in complaints from specific floors and gas consumption that climbs for no apparent reason.

We work on condensing water heaters and boilers designed for this use, as well as recirculation pumps and controls. The diagnosis always starts with the network before concluding with the appliance.

A Downed Boiler Room is a Building Emergency, Not an Individual Inconvenience

This is why calls are accepted from 7 a.m. to 11 p.m., seven days a week.

Heating a Garage, Warehouse, or Workshop

Suspended gas unit heaters remain the most direct solution for high-volume, poorly insulated spaces, where heating the air from the ceiling is cheaper than heating the mass. We install, repair, and inspect their venting.

The most frequently overlooked point is the air supply. A combustion appliance in an airtight room lacks air and will fail, sometimes causing backdrafting. In a service garage where vehicles are running inside, this is not a theoretical issue.

Corridor Fresh Air

In an apartment building, the make-up air unit that feeds the corridors does more than just ventilate: it keeps the corridors under slight positive pressure, which prevents odors and contaminants from moving from one unit to another. When it breaks down, the problem manifests as a complaint about odors or humidity, rarely as a ventilation failure.

We service these units, their gas heating sections, and their controls. See also our air treatment page.

What Changes for Owners Starting in 2027

The Regulation respecting the mandatory reporting of the environmental performance of certain buildings, published in the Gazette officielle du Québec on June 23, 2026, requires the reporting of energy consumption for certain buildings, including natural gas, with verification by a professional.

StartingTargeted Buildings
January 1, 2027Buildings with 50 units or more; buildings of 5,000 m² or more that are not exclusively residential
January 1, 2028Buildings with 25 units or more; buildings of 2,000 m² or more that are not exclusively residential

For a manager, this moves boiler room maintenance from an expense item to a data item: a poorly tuned boiler will now show up in a reported figure.

R.B.Q. 5840-4443-01

Valid license, verifiable in the Régie du bâtiment public register.

CMMTQ Member

Corporation des maîtres mécaniciens en tuyauterie du Québec.

10-year warranty, extended to 12

Gree parts and compressor, upon equipment registration.

Calls from 7 AM to 11 PM

Service and emergencies, seven days a week.

Frequently Asked Questions

Yes. We begin with an assessment of the existing setup: appliance, controls, network, and venting. A boiler room cannot be diagnosed over the phone.

We establish the frequency based on the appliance and the number of units served. Write to us so we can take a look at your building.

Calls are accepted from 7 a.m. to 11 p.m., seven days a week. Daytime and emergency rates are listed on the maintenance and repair page.

Yes, provided that the fresh air intake and venting are sized for the actual use of the space. This is the first thing we check.

Starting January 1, 2027 for 50 units or more, and January 1, 2028 for 25 units or more. Buildings under construction or subject to a demolition permit are excluded.

A free quote, with no pressure

We’ll come to you, take measurements, and explain what works best and why. Then, you decide.